bjat13261775404 发表于 2011-1-10 17:32:48

GE全系列探头供应 腹部 心脏 容积 小器官 腔内

GE LOGIQ 3 / 5/ 7/ 9 AND VIVID 3 / 5/ 7/ SYSTEM FIVE探头表TRANSDUCER MODEL      DESCRIPTION      MODEL ULTRASOUNDGE 3S      1-3MHz Cardiac Sector      Logiq 3/5/7 & Vivid 3/5/7/9GE 3Sr      1.5-2.6 MHz Cardiac Sector      Logiq 700/700 EXP/700 PROGE 3C      2-5.7 MHz Convex      Logiq 3/5/7/9, Vivid 5/7/9GE 3.5C      2-5MHz Convex      Logiq 3/5/7/9, Vividc 5/7/9GE 4C      3-6MHz Convex      Logiq 9 BT04 or aboveGE 4S      2-4MHz Sector      Logiq 7/9GE 5.0 CLA (KK100008)      5.0MHz Convex / 40mm      System Five & Vivid 5GE 5C      3.6-8.0 MHz Convex      Logiq 3,5 & 7, Vivid 3, 7GE 5S      3-6MHz Pediatric Cardiac      Logiq 5/7 & Vivid 3/5/7GE 5.0 TEE (TN100053E)      5.0 MHz TEE      CFM 775/800, System Five, 750--only if latest soft rev & bundy snap-on connectorsGE 5.0 MHZ TEE (TN100065)      5.0 MHz Pediatric TEE      Same as aboveGE 5T (KN100006) (Same as MPTE 5T)      5.0 MHz TEE      System Five & Vivid 5GE 6T (KN100093)      2.9 TO 6.8 MHz TEE      Logiq 6/7 & Vivid 3/4/7 PROGE 6T-OR (KN100092)?? (Same as 6T except shielded)      2.7 TO 7.0 MHz TEE      Logiq 6/7 & Vivid 3/4/7 PROGE 6T-RS      2.9 TO 6.8 MHz TEE      Vivid I (handheld u/s)GE 6TV (KN100062)      2.9 TO 6.7 MHz TEE      Logiq 5/7/9 & Viv id 3/7GE 7L      4-7MHz Linear      Logiq 3 Exp/5/7/9 & Vivid 3/5/7GE 7S      4-8MHz Pediatric Cardiac      Logiq 5/7 & Vivid 3/5/7GE 8C      4.0 to 10.0 MHz Convex      Logiq 3/5/7/9 & Vivid 3/7GE 8S      5-10 MHz Sector      Logiq 700/700 Pro/700 ExpGE 8.0 MHZ TEE (KN100010)      8.0 MHz TEE      Vivid 7GE 9T (KN100072)      2.7 to 7.0 MHz TEE      Vivid 7GE 9T-OR (KN100092)??      2.9 to 6.7 MHz TEE      Vivid 7GE 10LB      5-10MHz Linear      Logiq 3 / Logiq 3 Exp / 5/7/9/ & Vivid 3/5/7GE 10L      5-10MHz Linear      Logiq 3 Exp/5/7/9 & Vivid 3/5/7GE 10S      5-10MHz Cardiac Sector      Logiq 5/7 & Vivid 3/5/7GE 12L      6-12MHz Linear      Logiq 3 Exp/5/7/9 & Vivid 3/5/7GE BE7C      4.0 to 11.0 MHz endorectal, 127mm      Logiq 9 & 7, Vivid 3, 7GE E8C      4-9MHz Endocavity      Logiq 7/9/3 Exp, Vivid 3/7GE ERB7      Endorectal–biopsy      Logiq 200/400/500GE ERB9      Endorectal–bi-plane      Logiq 3GE CLA 3.5 (KK100001)      3.5MHz Convex      System Five & Vivid 5GE CLA 5.0 (KN100008)      5.0MHz Convex      System Five & Vivid 5GE FLA 5 (KN100003)      5.0 MHz linear / 60mm      System 5 / Vivid 5GE FLA 6      4.0-8.0 MHz linear      System 5 / Vivid 5GE FLA 10      10.0 MHz linear      System 5 / Vivid 5GE FPA 2.5 (KG100001)      2.0-4.0 phased array adult cardiac      System 5 & Vivid 5GE FPA 3.5 (KK100001 or KK100005)      3.5 MHz phased array adult cardiac      System 5 & Vivid 5GE FPA 5.0      4.0-7.0 phased array sm. adult cardiac      System 5 & Vivid 5GE FPA 10      5.0-10.0 phased array neonate cardiac      System 5 & Vivid 5GE M3C      3.75MHz Convex      Logiq 700MRGE M3S      1.5-3.6 MHz phased adult cardiac      Logiq 7, Vivid 7, Logiq S6
页: [1]
查看完整版本: GE全系列探头供应 腹部 心脏 容积 小器官 腔内